The post 05_Airtac TSAI Series With guide frame appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>
Specification:

Ordering Code:

Symbol:

The post 05_Airtac TSAI Series With guide frame appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>The post 07_Airtac SE Series Cylinder appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>1. ISO15552 and VDMA24562 standard cylinder;
2. The piston seal is composed of two Y-shape one-way seal structure, which has compensation function, long service life and low start-up pressure;
3. The square aluminum pipe without tie rod has good corrosion resistance;
4. The buffer adjustment of cylinder is smooth and steady;
5. Cylinders and accessories for installation with several specifications are optional.
Specification:

Installation & Usage:
1. When load changes in the work, the cylinder with abundant output capacity shall be ed.
2. Relative cylinder with high temperature resistance or corrosion resistance shall be chosen under the condition of high temperature or corrosion.
3.Necessary protection measure shall be taken in the environment with higher humidity, much dust or water drops, oil dust and welding dregs.
4.Dirty substances in the pipe must be eliminated before cylinder is connected with pipeline to prevent the entrance of particles into the cylinder.
5.The medium used by cylinder shall be filtered to 40μm or below.
6. Anti-freezing measure shall be adopted under low temperature environment to prevent moisture freezing.
7. The cylinder shall be carried out test run without load before application. Prior to run, buffer shall be turned to the minimum and gradually released to avoid the damage on cylinder caused by excessive impact.
8. The cylinder shall avoid the influence of side load in operation to maintain the normal work of cylinder and extend the service life.
9. If the cylinder is dismantled and stored for a long time, please conduct anti-rust treatment to the surface. Anti-dust caps shall be added in air inlet and outlet ports.
Ordering Code:

Symbol:

The post 07_Airtac SE Series Cylinder appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>The post 06_Airtac SGC Series Cylinder appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>1. ISO15552 (original ISO6431) standard cylinder.
2.The piston seal is composed of two Y-shape seals of single-direction structure, which has compensation function, long service life and low start-up pressure.
3.SGC series cylinders are made of aluminum pipe.
4.The buffer adjustment of cylinder is smooth and steady.
5.Cylinders and accessories for installation with several specifications are optional.
6.The seal material with high temperature resistance is adopted to guarantee the normal operation of cylinder at 150℃.
Specification:

Installation & Usage:
1. When load changes in the work, the cylinder with abundant output capacity shall be ed.
2.Relative cylinder with high temperature resistance or corrosion resistance shall be chosen under the condition of high temperature or corrosion.
3. Necessary protection measure shall be taken in the environment with higher humidity, much dust or water drops, oil dust and welding dregs.
4. Dirty substances in the pipe must be eliminated before cylinder is connected with pipeline to prevent the entrance of particles into the cylinder.
5. The medium used by cylinder shall be filtered to 40μm or below.
6. Anti-freezing measure shall be adopted under low temperature environment to prevent moisture freezing.
7.The cylinder shall be carried out test run without load before application. Prior to run, buffer shall be turned to the minimum and gradually released to avoid the damage on cylinder caused by excessive impact.
8.The cylinder shall avoid the influence of side load in operation to maintain the normal work of cylinder and extend the service life.
9. If the cylinder is dismantled and stored for a long time, please conduct anti-rust treatment to the surface. Anti-dust caps shall be added in air inlet and outlet ports.
Ordering Code:

Symbol:

The post 06_Airtac SGC Series Cylinder appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>The post 13_Airtac JSI Series Cylinder appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>1.JIS standard cylinder.
2.The seal of piston adopts heterogeneous two way seal structure. It’s dimension is tight and it has the function of greasel reservation.
3.The Mickey Mouse-shaped aluminum barrel of JSI series has no tie rod and good performance of corrosion resistance.
4.Compared with ISO15552 standard cylinder, the cylinder of JSI series with the same cylinder diameter is shorter.
5.The buffer adjustment of cylinder is smooth and steady.
6.Cylinders and mounting accessories for installation with several specifications are optional.
7.The seal material with high temperature resistance is adopted to guarantee the normal operation of cylinder at 150℃.
Specification:

Installation & Usage:
1.When load changes in the work, the cylinder with abundant output capacity shall be ed.
2.Relative cylinder with high temperature resistance or corrosion resistance shall be chosen under the condition of high temperature or corrosion.
3.Necessary protection measure shall be taken in the environment with higher humidity, much dust or water drops, oil dust and welding dregs.
4.Dirty substances in the pipe must be eliminated before cylinder is connected with pipeline to prevent the entrance of particles into the cylinder.
5. The medium used by cylinder shall be filtered to 40μm or below.
6. Anti-freezing measure shall be adopted under low temperature environment to prevent moisture freezing.
7.The cylinder shall be carried out test run without load before application. Prior to run, buffer shall be turned to the minimum and gradually released to avoid the damage on cylinder caused by excessive impact.
8.The cylinder shall avoid the influence of side load in operation to maintain the normal work of cylinder and extend the service life.
9. If the cylinder is dismantled and stored for a long time, please conduct anti-rust treatment to the surface. Anti-dust caps shall be added in air inlet and outlet ports.
Ordering Code:

Symbol:

The post 13_Airtac JSI Series Cylinder appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>The post 08_Airtac SC Series Cylinder appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>1.Standard cylinder manufactured by our enterprise.
2.The seal of piston adopts heterogeneous two way seal structure. It’s dimension is tight and it has the function of grease reservation.
3.It is tie rod cylinder. The cylinder barrel and front/rear cap is jointed by tie rods with high reliability.
4.Compared with ISO15552 standard cylinder, SC series cylinder with the same bore size is shorter.
5.The buffer adjustment of cylinder is smooth and steady.
6.Cylinders and mounting accessories with several specifications are optional.
7.The seal material with high temperature resistance is adopted to guarantee the normal operation of cylinder at 150℃.
Specification:

Installation & Usage:
1.When load changes in the work, the cylinder with abundant output capacity shall be ed.
2.Relative cylinder with high temperature resistance or corrosion resistance shall be chosen under the condition of high temperature or corrosion.
3.Necessary protection measure shall be taken in the environment with higher humidity, much dust or water drops, oil dust and welding dregs.
4.Dirty substances in the pipe must be eliminated before cylinder is connected with pipeline to prevent the entrance of particles into the cylinder.
5.The medium used by cylinder shall be filtered to 40μm or below.
6.Anti-freezing measure shall be adopted under low temperature environment to prevent moisture freezing.
7.The cylinder shall be carried out test run without load before application. Prior to run, buffer shall be turned to the minimum and gradually released to avoid the damage on cylinder caused by excessive impact.
8.The cylinder shall avoid the influence of side load in operation to maintain the normal work of cylinder and extend the service life.
9.If the cylinder is dismantled and stored for a long time, please conduct anti-rust treatment to the surface. Anti-dust caps shall be added in air inlet and outlet ports.
Ordering Code:

Symbol:

The post 08_Airtac SC Series Cylinder appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>The post 01_Airtac SAI Series Standard cylinder appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>1.ISO15552 (original ISO6431) standard cylinder;
2.The piston seal is composed of two Y-shape one-way seal structure, which has compensation function, long service life and low start-up pressure;
3.The米-shaped aluminum pipe without tie rod has good corrosion esistance. With sensor switch groove on the two sides of body;
4.The buffer adjustment of cylinder is smooth and steady;
5.Cylinders and accessories for installation with several specifications are optional.
Specification:

Installation & Usage:
1.When load changes in the work, the cylinder with abundant output capacity shall be ed.
2.Relative cylinder with high temperature resistance or corrosion resistance shall be chosen under the condition of high temperature or corrosion.
3.Necessary protection measure shall be taken in the environment with higher humidity, much dust or water drops, oil dust and welding dregs.
4.Dirty substances in the pipe must be eliminated before cylinder is connected with pipeline to prevent the entrance of particles into the cylinder.
5.The medium used by cylinder shall be filtered to 40μm or below.
6.Anti-freezing measure shall be adopted under low temperature environment to prevent moisture freezing.
7.The cylinder shall be carried out test run without load before application. Prior to run, buffer shall be turned to the minimum and gradually released to avoid the damage on cylinder caused by excessive impact.
8.The cylinder shall avoid the influence of side load in operation to maintain the normal work of cylinder and extend the service life.
9.If the cylinder is dismantled and stored for a long time, please conduct anti-rust treatment to the surface. Anti-dust caps shall be added in air inlet and outlet ports.
Ordering Code:

Symbol:

The post 01_Airtac SAI Series Standard cylinder appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>The post 02_Airtac SAIL Series–with locker type appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>1.With lock cylinder: front cover with lock type and rear cover lock type;
2.The way of unlocking: automatic and manual.
Specification:

Installation & Usage:
Ordering Code:

Symbol:

The post 02_Airtac SAIL Series–with locker type appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>The post 04_Airtac BSAI Series–Enclasp type appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>1.Belong to SAI series standard cylinder add lock structure.
2.Can be locked at random positions in stroke scope.
3.Reasonable lock structure, the lock state no relation with the direction of piston moving.
Specification:

Installation & Usage:

Symbol:

The post 04_Airtac BSAI Series–Enclasp type appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>The post 11_Airtac SAU Series Standard cylinder appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>1.Standard cylinder manufactured by our enterprise.
2.The seal of piston adopts heterogeneous two way seal structure. It’s dimension is tight and it has the function of oil reservation.
3.It is no tie rod cylinder. The cylinder barrel is “Mickey Mouse” shape ,and have good corrosion.
4.Compared with ISO15552 standard cylinder, SU series cylinder with the same bore size is shorter.
5.The buffer adjustment of cylinder is smooth and steady.
6.Mounting accessories are the same as SC series.
7.The seal material with high temperature resistance is adopted to guarantee the normal operation of cylinder at 150℃.
Specification:

Installation & Usage:
1.When load changes in the work, the cylinder with abundant output capacity shall be ed.
2.Relative cylinder with high temperature resistance or corrosion resistance shall be chosen under the condition of high temperature or corrosion.
3.Necessary protection measure shall be taken in the environment with higher humidity, much dust or water drops, oil dust and welding dregs.
4.Dirty substances in the pipe must be eliminated before cylinder is connected with pipeline to prevent the entrance of particles into the cylinder.
5.The medium used by cylinder shall be filtered to 40μm or below.
6.Anti-freezing measure shall be adopted under low temperature environment to prevent moisture freezing.
7.The cylinder shall be carried out test run without load before application. Prior to run, buffer shall be turned to the minimum and gradually released to avoid the damage on cylinder caused by excessive impact.
8.The cylinder shall avoid the influence of side load in operation to maintain the normal work of cylinder and extend the service life.
9.If the cylinder is dismantled and stored for a long time, please conduct anti-rust treatment to the surface. Anti-dust caps shall be added in air inlet and outlet ports.
Ordering Code:

Symbol:

The post 11_Airtac SAU Series Standard cylinder appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>The post 09_Airtac SC Series–Big bore size type appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>1.ISO6430 standard cylinder.
2.The seal of piston adopts heterogeneous two way seal structure. It’s dimension is tight and it has the function of grease reservation.
3.It is tie rod cylinder. The cylinder barrel and front/rear cap is jointed by tie rods with high reliability.
4.Compared with ISO15552 standard cylinder, SC series cylinder with the same bore size is shorter.
5.The buffer adjustment of cylinder is smooth and steady.
6.Cylinders and mounting accessories with several specifications are optional.
7.The seal material with high temperature resistance is adopted to guarantee the normal operation of cylinder at 150℃.
Specification:

Installation & Usage:
1.When load changes in the work, the cylinder with abundant output capacity shall be ed.
2.Relative cylinder with high temperature resistance or corrosion resistance shall be chosen under the condition of high temperature or corrosion.
3.Necessary protection measure shall be taken in the environment with higher humidity, much dust or water drops, oil dust and welding dregs.
4.Dirty substances in the pipe must be eliminated before cylinder is connected with pipeline to prevent the entrance of particles into the cylinder.
5.The medium used by cylinder shall be filtered to 40μm or below.
6.Anti-freezing measure shall be adopted under low temperature environment to prevent moisture freezing.
7.The cylinder shall be carried out test run without load before application. Prior to run, buffer shall be turned to the minimum and gradually released to avoid the damage on cylinder caused by excessive impact.
8.The cylinder shall avoid the influence of side load in operation to maintain the normal work of cylinder and extend the service life.
9.If the cylinder is dismantled and stored for a long time, please conduct anti-rust treatment to the surface. Anti-dust caps shall be added in air inlet and outlet ports.
Ordering Code:

Symbol:

The post 09_Airtac SC Series–Big bore size type appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>