The post Airtac 7S Series Integrated solenoid valve appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>
Specification:

Installation & Usage:

Ordering Code:

The post Airtac 7S Series Integrated solenoid valve appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>The post Airtac ADW Series appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>1.The float is with lever structure. Low position enables more stable drain.
2.The bowl made of High intensity PC and covered by steel case is safer to use.
3.Double strainer guarantees the operation of the drainer.
4.Inlet with large port size prevents accumulation of particles or rust.
5.The drainage bowl with large capacity can keep more rust and dirt than general drains.
6.The drain is equipped with large float and sensitive to control.
7.The bowl with large size can store a certain amount of water which reduces discharging time and extends the service life.
Specification:

Installation & Usage:
1.ADW400 series are applicable to following air compressing equipments: air storage tank, dryer, filter, and piping.
2.Minimum 300mm room is required if the bottom end of above-mentioned equipments being connected with a (1/2″) joint.
3.Using a 1/2″ hand lever valve between the air compressing equipment and the inlet of ADW400 is good for maintenance.
4.The air displacement of the air compressing equipment can’t be lower than 182 L/min.
5.Make sure the drain is vertical downward and the drain pipe is not bended upside.
6.Do not use acidoid or volatile oil gas (hydrochloric acid, petrol, methylbenzene, etc.) to clean the PC bowl. This may cause break.
7.Push the hexagon nut of the body to release the residual pressure before dissembling the PC bowl and metal protection case to avoid any injury or harm.
Ordering Code:

The post Airtac ADW Series appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>The post 11_Airtac GC Series appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>1.Oil dripping adopts gap seal structure, which makes the adjustment of oil supply more reliable.
2.Oil feed ring can only make one full turn. The quantity of oil supply, basically taking on linear distribution. The quantity of oil supply can be generally calculated according to the position of graduation ring.
3.Filling of oil while the lubricator is under pressure is made possible.
4.Special drip nozzle structure will produce negative pressure in oil dripping outlet and the mist flow is minimal.
5.Quick and reliable mounting clamps makes it convenient to install and use.
6.The performance of pressure adjustment is reliable with high precision.
7.The efficiency of eliminating moisture and solid grain is high.
8.Three drain types are available: manual drain, semiauto drain and automatic drain.
Specification:

Installation & Usage:
1.Check whether the components have been damaged during transportation before installing and using.
2.Pay attention to whether the flow direction of air (notice “→” direction) and thread type are correct.
3.Please notice whether installation condition accords with technical requirements (such as “working pressure” and “applied temperature range”);
4.Avoid usage in an environment that exposes the filter and lubricator bowl through contact with Chlorine, solvent, aromatic essence, acid and alkali to avoid damage to the Filter and Lubricator bowl.
5.Regularly clean or change filter core. Lubricators and regulators shall be in descending order.
6.Keep the dust away. The dust cover shall be installed in intake and outlet when the device is dismantled and stored.
Ordering Code:

CLICK ABOVE FOR DOWNLOAD
The post 11_Airtac GC Series appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>The post 12_Airtac GF Series appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>1.Unique diversion structure spins the air flowing through to effectively separate the liquid from the air and reliably filter the solid grain.
2.It has low pressure loss, high efficiency in separating water and large drain bowl capacity.
3.Filtering grade includes 5μm and 40μm (Optional).
4.Three drain types are available: manual drain, semi-auto drain and automatic drain.
5.The bracket can be ed for installation.
Specification:

Installation & Usage:
1.Check whether the components have been damaged during transportation before installing and using.
2.Pay attention to whether the flow direction of air (notice “→” direction) and thread type are correct.
3.Please notice whether installation condition accords with technical requirements (such as “working pressure” and “applied temperature range”);
4.Avoid usage in an environment that exposes the filter and lubricator bowl through contact with Chlorine, solvent, aromatic essence, acid and alkali to avoid damage to the Filter and Lubricator bowl.
5.Regularly clean or change filter core. Lubricators and regulators shall be in descending order.
6.Keep the dust away. The dust cover shall be installed in intake and outlet when the device is dismantled and stored.
Ordering Code:

CLICK ABOVE FOR DOWNLOAD
The post 12_Airtac GF Series appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>The post 13_Airtac GFC Series appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>1.Quick and reliable mounting clamps makes it convenient to install and use.
2.The performance of pressure adjustment is reliable with high precision.
3.The efficiency of eliminating moisture and solid grain is high.
4.Three drain types are available: manual drain, semi-auto drain and automatic drain.
Specification:

Installation & Usage:
1.Check whether the components have been damaged during transportation before installing and using.
2.Pay attention to whether the flow direction of air (notice “→” direction) and thread type are correct.
3.Please notice whether installation condition accords with technical requirements (such as “working pressure” and “applied temperature range”);
4.Avoid usage in an environment that exposes the filter and lubricator bowl through contact with Chlorine, solvent, aromatic essence, acid and alkali to avoid damage to the Filter and Lubricator bowl.
5.Regularly clean or change filter core. Lubricators and regulators shall be in descending order.
6.Keep the dust away. The dust cover shall be installed in intake and outlet when the device is dismantled and stored.
Ordering Code:

CLICK ABOVE FOR DOWNLOAD
The post 13_Airtac GFC Series appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>The post 14_Airtac GFR Series appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>1.Embedded square pressure gauge is used to save installation space. (External circular pressure gauge is also optional).
2.The pressed-in self-locking mechanism can prevent the abnormal movement of the set pressure caused by external interfere.
3.Balanced design is adopted for the pressure adjustment mechanism.
4.In addition to standard type, lower pressure type is optional (The highest adjustable pressure is 0.4MPa).
5.Unique diversion structure spins the air flowing through to effectively sparate the liquid from the air and reliabily filter the solid grain.
6.The filtering grade includes 5μm and 40μm (optional).
7.Three drain types are available: manual drain, semiauto drain and automatic drain.
8.The bracket can be ed for installation.
Specification:

Installation & Usage:
1.Check whether the components have been damaged during transportation before installing and using.
2.Pay attention to whether the flow direction of air (notice “→” direction) and thread type are correct.
3.Please notice whether installation condition accords with technical requirements (such as “working pressure” and “applied temperature range”);
4.Avoid usage in an environment that exposes the filter and lubricator bowl through contact with Chlorine, solvent, aromatic essence, acid and alkali to avoid damage to the Filter and Lubricator bowl.
5.Regularly clean or change filter core. Lubricators and regulators shall be in descending order.
6.Keep the dust away. The dust cover shall be installed in intake and outlet when the device is dismantled and stored.
Ordering Code:

CLICK ABOVE FOR DOWNLOAD
The post 14_Airtac GFR Series appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>The post 16_Airtac GR Series appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>1.Embedded square pressure gauge is used to save installation space. (External circular pressure gauge is also optional).
2.The pressed-in self-locking mechanism can prevent the abnormal movement of the set pressure caused by external interfere.
3.Balanced design is adopted for the pressure adjustment mechanism.
4.In addition to panel installation, the bracket is optional for installation.
5.In addition to standard type, lower pressure type is optional (the highest adjustable pressure is 0.4MPa).
Specification:

Installation & Usage:
1.Check whether the components have been damaged during transportation before installing and using.
2.Pay attention to whether the flow direction of air (notice “→” direction) and thread type are correct.
3.Please notice whether installation condition accords with technical requirements (such as “working pressure” and “applied temperature range”);
4.Avoid usage in an environment that exposes the filter and lubricator bowl through contact with Chlorine, solvent, aromatic essence, acid and alkali to avoid damage to the Filter and Lubricator bowl.
5.Regularly clean or change filter core. Lubricators and regulators shall be in descending order.
6.Keep the dust away. The dust cover shall be installed in intake and outlet when the device is dismantled and stored.
Ordering Code:

CLICK ABOVE FOR DOWNLOAD
The post 16_Airtac GR Series appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>The post 15_Airtac GL Series appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>1.The structure of oil dripping adopts gap seal type, which makes the adjustment of oil supply more reliable.
2.Oil feed ring can only make one full turn.The quantity of oil supply basically takes on linear distribution. The quantity of oil supply can be generally calculated according to the position of graduation ring.
3.Special drip nozzle structure will produce negative pressure in oil dripping outlet and the mist flow is minimal.
4.Filling of oil while the lubricator is under pressure is made possible, and the oil bowl is large;
5.The bracket can be ed for installation.
Specification:

Installation & Usage:
1.Check whether the components have been damaged during transportation before installing and using.
2.Pay attention to whether the flow direction of air (notice “→” direction) and thread type are correct.
3.Please notice whether installation condition accords with technical requirements (such as “working pressure” and “applied temperature range”);
4.Avoid usage in an environment that exposes the filter and lubricator bowl through contact with Chlorine, solvent, aromatic essence, acid and alkali to avoid damage to the Filter and Lubricator bowl.
5.Regularly clean or change filter core. Lubricators and regulators shall be in descending order.
6.Keep the dust away. The dust cover shall be installed in intake and outlet when the device is dismantled and stored.
Ordering Code:

The post 15_Airtac GL Series appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>The post 08_Airtac GA Series appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>1.It is installed between G series regulator (or filter & regulator) and G series Lubricator. The air flow is divided by the device that one enters Lubricator to supply oil for lubrication and the other (the second way) directly enters the equipment.
2.Several kinds of bracket can be ed to connect regulator and lubricator. Optional brackets are type T, type L and type U.
Specification:

Installation & Usage:
1.Check whether the components have been damaged during transportation before installing and using.
2.Pay attention to whether the flow direction of air (notice “→” direction) and thread type are correct.
3.Please notice whether installation condition accords with technical requirements (such as “working pressure” and “applied temperature range”);
4.Avoid usage in an environment that exposes the filter and lubricator bowl through contact with Chlorine, solvent, aromatic essence, acid and alkali to avoid damage to the Filter and Lubricator bowl.
5.Regularly clean or change filter core. Lubricators and regulators shall be in descending order.
6.Keep the dust away. The dust cover shall be installed in intake and outlet when the device is dismantled and stored.
Ordering Code:

The post 08_Airtac GA Series appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>The post 09_Airtac GA315 Series appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>1.This reverse flow valve can be used with GA series regulator but can not be ordered individually.
2.When it is used with GA series regulator, one only needs to change the seal board in the back of regulator for the reverse flow valve. It is convenient to install and won’t change the external dimension of regulator.
Specification:

Installation & Usage:

The post 09_Airtac GA315 Series appeared first on Samux | AirTAC Distributer | ATTEN Distributer | Soldering Station | Dealer | Supplier | Air Tac | Airtacindia | Airtac India.
]]>